Zen-Xero DYNAMIX Safety Data

Zen-Xero Dynamix Safety Data -

#1 - SECTION 2: HAZARDS IDENTIFICATION

GHS Classification:

Acute toxicity oral: Not classified under GHS criteria

Acute toxicity dermal: Not classified under GHS criteria

Flammable liquids: Category 2, thinner

Reproductive toxicity: Category 1B, silicone

Serious eye damage/eye irritation: Category 2B, thinner

STOT SE / respiratory irritation, narcotic effects: Category 3, thinner

Aquatic toxicity: Category 3, fluorinated compounds and thinner

Symbol: Corrosive, Health hazard, Flame Signal word: Danger

Hazard Pictogram:

 

 

Hazard Statements: May cause allergic skin reaction Causes eye irritation Flammable liquid and vapor Causes skin irritation May damage fertility or the unborn child May cause damage to organs (central nervous system, visual organs, systemic toxicity, respiratory tract irritation, narcotic effects) if inhaled May cause damage to organs (central nervous system, visual organs) through prolonged or

repeated exposure or inhalation Very toxic to aquatic life Very toxic to aquatic life with long lasting effects

#2 Precautionary statements: Do not handle until all safety precautions have been read and understood. Avoid breathing dust/fume/gas/mist/vapors/spray. Wash hands thoroughly after handling. Use only outdoors or in a well-ventilated area. Do not take contaminated work clothing out of the workplace. Wear protective gloves and mask. Keep the container tightly sealed and store in a dark place.

#3. SECTION 4: FIRST AID MEASURES

General advice If symptoms persist or if in doubt, seek medical advice.

If in eyes Immediately flush the eyes thoroughly with plenty of water for at least 15 minutes, including under the eyelids. Remove contact lenses if they can be easily taken out, and continue rinsing. Move the eyes in all directions to ensure water reaches every part.

If on skin Remove contaminated clothing. If irritation appears, seek medical attention. Wash the affected area thoroughly with soap and water. Wash contaminated clothing before reuse.

If inhaled Move the person to an area with fresh air. Cover with a blanket to keep warm and allow the person to rest. If breathing becomes difficult, loosen clothing, ensure an open airway, administer oxygen or artificial respiration, and seek immediate medical attention. Let the person rest in a position that makes breathing easier. If exposure or concern arises, get medical advice and treatment. If unconscious, place in the recovery position and follow medical instructions. If symptoms persist, consult a physician.

If swallowed Immediately contact a doctor or poison control center. Do not induce vomiting unless directed by medical personnel. Do not give anything by mouth to an unconscious person. Aspiration into the lungs may cause chemical pneumonitis. Rinse the mouth thoroughly with water if possible. Aspiration into the lungs may cause chemical pneumonitis.

Most important symptoms and effects No data available.

Special notes for physicians No data available.

4 and 5. SECTION 7: HANDLING AND STORAGE

Handling technical measures: Implement equipment control measures as described in Section 8. Wear protective equipment. Ground the containers and install grounding devices. Use only non-sparking tools. Use explosion-proof electrical equipment, ventilation systems, and lighting. Take measures to prevent static discharge. Install local exhaust ventilation when vapors, fumes, or mists are likely to be generated. Install eye-wash and body-wash stations near the handling area.

Precautions for safe handling: Wear protective gloves, goggles, and face protection. Do not eat, drink, or smoke when using this product. Wash hands thoroughly after handling. Use only outdoors or in a well-ventilated area. Store in a cool location. Avoid inhalation of dust, smoke, gas, mist, vapor, or spray.

Conditions for safe storage: Avoid contact: Refer to Section 10.

Safe storage conditions: Refer to Section 10. Store locked up. Store in a well-ventilated place in tightly closed containers.

6. SECTION 13: DISPOSAL CONSIDERATIONS

Residues: Prior to disposal, neutralize, stabilize, or detoxify the material as much as possible to reduce its hazardous properties. Entrust the disposal of contents/containers to a licensed industrial waste disposal company approved by the prefectural governor. Contaminated containers and packaging: Clean containers for recycling, or dispose of properly according to local regulations. Ensure all contents are removed before discarding empty containers. Be cautious when incinerating, as the product contains flammable substances.

Quickly remove combustible materials from the area. Fight the fire from the upwind side whenever possible. Use dry chemical, carbon dioxide, or dry sand for initial fires. For large fires, use foam extinguishing agents to block air and extinguish rapidly. In case of surrounding fires, spray nearby equipment and structures with water to cool and relocate if necessary.

Protection for firefighters Wear self-contained breathing apparatus if required. Wear suitable protective equipment (e.g., flame-resistant clothing).

7. Direction for use.

- Zen-Xero Dynamix is intended to be applied over Accelerator. While it can be applied independently, we strongly suggest using both products as the intended installation process for maximum bonding and increased film thickness of Dynamix.

Hand Application

Dynamix should be applied no sooner than 1 hour (60 minutes) after the installation of Accelerator.

Apply Dynamix with provided applicator and wait 1-2 minutes for product to set up.

Using a damp towel (rung out and not dripping), wipe the surface and remove the excess residue and activate the catalyst to begin hardening, then wipe the panel clean with a second clean microfiber towel.

If the application process seems thick and sticky, it is time to replace the applicator. If the coating is becoming difficult to wipe off with the damp towel, we recommend replacing that towel with a new damp towel.

IR curing is not necessary but can speed up curing and ability to release to the customer quicker. Without IR cure, Dynamix should stay dry and indoors for 24 hours before being exposed to the natural elements.

-          Do not get wet for 24 hours after application

-          Do not wash for 1 week.

---- For full SDS, please contact DavidPatterson@echeloncoatings-usa.com