Echelon Hydrorepel Safety Data
Hydrorepeal Safety Data =
#1 - SECTION 2: HAZARDS IDENTIFICATION
GHS Classification:
Flammable liquids – Category 3
Specific target organ toxicity — Repeated exposure – Category 1
Hazard Pictograms:


Signal Word: Danger
Hazard statements:
H226 - Flammable liquid and vapor
H372 - Causes damage to organs through prolonged or repeated exposure
2. Precautionary statements:
P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No
smoking.
P233 - Keep container tightly closed.
P240 - Ground/Bond container and receiving equipment.
P241 - Use explosion-proof electrical/ventilating/lighting equipment. P242 - Use only non-sparking
tools.
P243 - Take precautionary measures against static discharge.
P260 - Do not breathe fume, mist, spray, vapors.
P264 - Wash hands, forearms and face thoroughly after handling. P270 - Do not eat, drink or smoke
when using this product.
P280 - Wear eye protection, protective clothing, protective gloves.
P303+P361+P353 - If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin
with water/shower.
P314 - Get medical advice/attention if you feel unwell.
P370+P378 - In case of fire: Use carbon dioxide (CO₂), dry extinguishing powder, foam to
extinguish.
P403+P235 - Store in a well-ventilated place. Keep cool.
P501 - Dispose of contents/container to hazardous or special waste collection point, in
accordance with local, regional, national and/or international regulation.
3. SECTION 4: FIRST AID MEASURES
General measures: Never give anything by mouth to an unconscious person. If you feel unwell, seek medical advice (show the label where possible).
If inhaled: Allow affected person to breathe fresh air. Allow the victim to rest.
If on skin: Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation persists, consult a doctor/medical service.
If swallowed: Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.
Most important symptoms and effects (acute and delayed): Based on available data, the classification criteria are not met.
Symptoms/effects after eye contact: Causes serious eye irritation.
Immediate medical attention and special treatment, if necessary: No additional information available.
4 and 5. SECTION 7: HANDLING AND STORAGE
Additional hazards when processed: Handle empty containers with care because residual vapors are flammable.
Precautions for safe handling: Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapor. No open flames. No smoking. Take precautionary measures against static discharge. Use only non-sparking tools.
Hygiene measures: Wash hands and other exposed areas with mild soap and water thoroughly after handling.
Technical measures: Proper grounding procedures to avoid static electricity should be followed. Ground/bond container and receiving equipment. Use explosion-proof equipment. Provide local exhaust or general room ventilation.
Storage conditions: Keep only in the original container in a cool, well ventilated place. Keep container tightly closed.
Incompatible products: Strong bases. Strong acids.
Incompatible materials: Sources of ignition. Direct sunlight. Heat sources.
6. SECTION 13: DISPOSAL CONSIDERATIONS
Waste treatment methods:
Sewage disposal recommendations: Do not allow the product to be released into the environment. Dispose in a safe manner in accordance with local/national regulations.
Product/Packaging disposal recommendations: Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.
Ecology - waste materials: Avoid release to the environment.
7. Directions. –
Hydrorepel is designed to be applied apx 1 hour after V3 has been installed. Apply Hydrorepel to the supplied applicator and apply evenly to the painted surface using light pressure. The product will dissipate and flash from the surface while being applied, but suggest wiping the surface with a clean microfiber towel after applied to the entire panel, to remove any residue that remains on the surface. The application of Hydrorepel is only useful when applied on freshly installed V4. Hydrorepel is not a topcoat or product that is reapplied to the surface for maintenance purposes. Please refer to website for water-based silica topcoat for regular maintenance usage.
Professional Installers contact us for full SDS forms.